Compact and Reliable General Purpose Power Supplies

Description

TRIO Power supplies, the new line of general purpose power supplies from Phoenix Contact, provide maximum power quality and reliability in a compact form factor. With rugged, zinc-plated steel housing measuring between 32 and 115mm wide, the TRIO occupies less space than most DIN-rail-mounted power supplies. The TRIO addresses applications requiring 2.5 to 20 amps of 24-volt DC power and features the same power output regulation as Phoenix Contact’s QUINT, MINI and STEP power supply products. Like those products, the TRIO has a Mean Time Between Failure (MTBF) rating of >500,000 hours, in accordance with IEC 61709, at nominal load and high 40° Celsius test standard. In addition, the TRIO is backed by a five-year USA warranty. The TRIO operates in temperatures ranging from zero to 70° Celsius and features a 55° Celsius (131° Fahrenheit) nominal operating temperature without de-rating. Other features include built-in LED diagnostic indication, adjustable 22.5-29.5 volt DC output and three DC grounding terminals. The wide, universal AC voltage input and international approvals, such as CE and UL 508 Listing, make the TRIO ideal for worldwide use

Specs

• Nominal input voltage 100 V AC ... 240 V AC • AC input voltage range 85 V AC ... 264 V AC (Derating < 90 V AC: 2.5%V) • DC input voltage range 100 V DC ... 350 V DC (UL508: 100 ... 250 V) • AC frequency range 45 Hz ... 65 Hz • DC frequency range 0 Hz • Current consumption Approx. 0.95 A (230 V AC)  A (230 V AC) • Approx. 1.7 A • 1.8 A (120 V AC) • Inrush surge current < 44 A (< 1.3 A2s) • Power failure bypass (refer to the diagram) • Buffer period (Depends on the storage medium, e.g. 20 min / 5 A) • Input fuse 6.3 A (slow-blow, internal) • Permissible backup fuse 6 A (characteristic B) • 10 A (Characteristic B) • 16 A (characteristic B) • Power factor (cos phi) Approx. 0.5 • Name of protection Transient surge protection • Protective circuit/component Varistor • Output data • Nominal output voltage 24 V DC • Setting range of the output voltage 22.5 V DC ... 29.5 V DC (Network operation; in the buffer mode, dependent on the battery voltage of 27.9 V DC ... 19.2 V DC) • Output current 5 A (-25 °C to +55 °C) • Derating From +55°C to 70°C: 2.5% per Kelvin • Connection in parallel Yes, 2 • Connection in series Yes • Control deviation < 1 % (change in load, static 10% ... 90%) • Residual ripple < 10 mVPP • Peak switching voltages nominal load < 25 mVPP • General data • Width 60 mm • Height 130 mm • Depth 118 mm • Weight 1.1 kg • Memory medium External, battery 1.3 Ah / 3.4 Ah / 7.2 Ah / 12 Ah • Efficiency > 88 % (230 V AC, network operation)  86 % (120 V AC, network operation)  86 % (Battery operation) • Insulation voltage input/output 2 kV (routine test) • 4 kV (type test) • Degree of protection IP20 • Class of protection I, with PE connection • MTBF > 500 000 h in acc. with IEC 61709 (SN 29500) • Ambient temperature (operation) -25 °C ... 70 °C (> 55° C derating) • Ambient temperature (storage/transport) -40 °C ... 80 °C • Max. permissible relative humidity (operation) 95 % (at 25 °C, no condensation) • Mounting position Horizontal DIN rail NS 35, EN 60715 • Assembly instructions Can be aligned: Horizontal 0 cm, vertical 5 cm • Electromagnetic compatibility Conformance with EMC guideline 2004/108/EC and for low-voltage guideline 2006/95/EC • Emitted interference EN 50081-2 • Immunity to interference EN 61000-6-2:2005 • Standard – Electrical equipment of machines EN 60204 • Standard - Safety of transformers EN 61558-2-17 • Standard - Electrical safety EN 60950/VDE 0805 (SELV) • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) • Standard – Safety extra-low voltage EN 60950 (SELV) • EN 60204 (PELV) • Standard - Safe isolation DIN VDE 0100-410 • DIN VDE 0106-1010 • Standard – Protection against electric shock DIN 57100-410 • Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment DIN VDE 0106-101 • Standard – Limitation of mains harmonic currents EN 61000-3-2 • UL approvals UL/C-UL listed UL 508 • UL/C-UL Recognized UL 60950 • Connection data, input • Type of connection Screw connection • Conductor cross section solid min. 0.2 mm² • Conductor cross section solid max. 2.5 mm² • Conductor cross section stranded min. 0.2 mm² • Conductor cross section stranded max. 2.5 mm² • Conductor cross section AWG/kcmil min. 24 • Conductor cross section AWG/kcmil max 12 • Screw thread M3 • Connection data, output • Type of connection Pluggable screw connection • Conductor cross section solid min. 0.2 mm² • Conductor cross section solid max. 2.5 mm² • Conductor cross section stranded min. 0.2 mm² • Conductor cross section stranded max. 2.5 mm² • Conductor cross section AWG/kcmil min. 24 • Conductor cross section AWG/kcmil max 12 • Stripping length 8 mm • Signaling • Output name Alarm • Output description Relay output • Output voltage + 24 V • Status display LED green • Note on status display Mains voltage OK: Green LED, static at • Conductor cross section solid min. 0.2 mm² • Conductor cross section solid max. 2.5 mm² • Conductor cross section stranded min. 0.2 mm² • Conductor cross section stranded max. 2.5 mm² • Conductor cross section AWG/kcmil min. 24 • Conductor cross section AWG/kcmil max 12 • Tightening torque, min 0.5 Nm • Tightening torque max 0.6 Nm • Screw thread M3 • Output name Alarm • Output description Relay output • Maximum switching voltage ≤ 24 V • Output voltage 24 V • Continuous load current ≤ 200 mA • Status display Alarm • Note on status display Red LED, static at • Output name Battery charge • Output description Relay output • Maximum switching voltage ≤ 24 V • Output voltage 24 V • Continuous load current ≤ 200 mA • Status display Battery (battery charge) is being charged • Note on status display Yellow LED, flashing • Output name Battery mode • Output description Relay output • Type of signaling LED, active relay output • Maximum switching voltage ≤ 24 V • Output voltage 24 V • Continuous load current ≤ 200 mA • Status display Battery operation (Battery Mode) • Note on status display LED yellow, static at • Charging process • Charge characteristic curve I/U characteristic curve • Battery presence check/time interval 60 s • Charge current 0.2 A ... 1.5 A (Default 1.0 A) • End-of-charge voltage 25 V DC ... 30 V DC (Default 27.6 V DC) • Temperature compensation 0 mV/K ... 200 mV/K (42 mV/K by default) • Quality check of battery 4 h ... 200 h (Default 12 h) • Deep discharge protection 18 V DC ... 21 V DC (Default 19.2 V DC) • Alarm signaling threshold 18 V DC ... 30 V DC (Default 20.4 V DC)
Be the first to review this product
Add your review:
RELATED STORIES