"Smart" And Compact Switchgear

Description

ReliaGear UL 1558 low-voltage (LV) switchgear is equipped with 100%-rated Emax 2 circuit breakers with embedded logic capabilities that make the switchgear safer and more compact, flexible, and reliable.

 

“Smart” features enable ReliaGear UL 1558 LV switchgear to be integrated fully into smart grids, buildings and industrial plants. Some of these features include a synchro-check function integrated into the trip unit, automatic transfer scheme options, simultaneous or redundant communications, seven industrial protocols, a power controller function, a network analyzer, and generator protection functions. ReliaGear UL 1558 LV switchgear also offers among the smallest footprints in the industry, with the main-tie-main breaker contained in one section and widths ranging from 18-38 in. and section depths of 72 or 84 in.

 

ReliaGear UL 1558 LV switchgear fosters safety and reliability with safety shutters and insulating barriers between sections and around the bus compartment to isolate it from the cable compartment. Additionally, no ventilation is required in the front of the equipment. Optional safety measurements include arc flash detection, arc mitigation solutions, and remote operation of circuit breakers with the Ekip Link system.

 

UL 1558 LV switchgear also has field-interchangeable trip units: Ekip for distribution protection and Ekip G for generator protection. Rogowski coils eliminate the need to replace current transformers when adjusting the circuit breaker current rating. Other features include standard built-in top and bottom horizontal wireways for control wires with no additional height and standard white paint mounting pans provided for each instrument compartment.

Specs

Features:

  • Doors are manufactured in 12 gauge steel
  • Shutter lock for up to three 4mm/0.15-in. – 8mm/0.31-in. padlocks.
  • Standard built-in top and bottom horizontal wireways for control wires with no additional height.
  • Standard white paint mounting pans are provided in each instrument compartment.
  • Field interchangeable trip units divided in two families: Ekip for distribution protection and Ekip G for generator protection. Rogowski coils eliminate the need to replace current transformers when adjusting the circuit breaker current rating
  • Standard insulating barriers to isolate the bus compartment from the cable compartment.
  • Standard rear covers or optional left/right hinged rear doors for access to the cable compartment.
  • Silver or tin plated ¼ in. x 4 in. ground bus mounted at bottom of the enclosure as standard with factory or field changeable option for top mounting.
  • Optional insulated bus Standard silver plated bus or optional tin plated bus