Virtual HMI” Gives Users Easy PC Access to Multi-Zone Controller

Description

“Virtual HMI” Gives Users Easy PC Access to Multi-Zone Controller
Master Controller module lets users create a “virtual HMI,” allowing machines to be controlled and monitored via any networked PC with a standard web browser. This also facilitates access and control of any connected device in the system, including PLCs and motor drives. Red Lion Controls, Inc., York, PA

Specs

• POWER: 24 VDC ± 10% • 400 mA min. (1 module) • 3.5 Amps max. (16 modules + Expansion Card) • Must use NEC Class 2 or Limited Power Source (LPS) rated power supply. • COMMUNICATIONS: • USB/PG Port: Adheres to USB specification 1.1. Device only using Type B • connection. • Serial Ports: Format and Baud Rates for each port are individually software • programmable up to 115,200 baud. • RS232/PG Port: RS232 port via RJ12 • COMMS Ports: RS422/485 port via RJ45, and RS232 port via RJ12 • DH485 TXEN: Transmit enable; open collector, VOH = 15 VDC, • VOL = 0.5 V @ 25 mA max. • Note: For additional information on the communications or signal common • and connections to earth ground please see the “Connecting to Earth • Ground” in the section “Installing and Powering the CSMSTRSX.” • Ethernet Port: 10 BASE-T / 100 BASE-TX • RJ45 jack is wired as a NIC (Network Interface Card). • LEDs: • STS – Status LED indicates condition of master. • TX/RX – Transmit/Receive LEDs show serial activity. • Ethernet – Link and activity LEDs. • CF – CompactFlash LED indicates card status and read/write activity • MEMORY: • On-board SDRAM: 2 Mbytes • Memory Card: CompactFlash Type II slot for Type I and Type II cards. • Used for optional database storage only. • REAL-TIME CLOCK: Typical accuracy is less than one minute per month drift. • Battery: Lithium Coin Cell. Typical lifetime of 10 years at 25 ºC. • A “Battery Low” system variable is available so that the programmer can • choose specific action(s) to occur when the battery voltage drops below • its nominal voltage. • This unit is NOT field serviceable. All work must be done by a qualified technician. • ENVIRONMENTAL CONDITIONS: • Operating Temperature Range: 0 to 50°C • Storage Temperature Range: -30 to +70°C • Operating and Storage Humidity: 80% max relative humidity, • non-condensing, from 0 to 50°C • Vibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z • direction for 1.5 hours, 2 g’s. • Shock According to IEC 68-2-27: Operational 25 g, 11 msec in 3 directions. • Altitude: Up to 2000 meters • CONSTRUCTION: Case body is burgundy high impact plastic and stainless • steel. For indoor use only. Installation Category II, Pollution Degree 2. • POWER CONNECTION: Removable wire clamp screw terminal block. • Wire Gage Capacity: 24 AWG to 12 AWG • Torque: 4.45 to 5.34 in/lb (0.5 to 0.6 N-m) • MOUNTING: Snaps onto standard DIN style top hat (T) profile mounting • rails according to EN50022 -35 x 7.5 and -35 x 15. • CERTIFICATIONS AND COMPLIANCES: • SAFETY • UL Listed, File #E302106, UL508, CSA 22.2 No. 14-M05 and File #E179259, • UL61010-1, CAN/CSA-C22.2 No. 61010-1 • LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards • IECEE CB Scheme Test Report #E179259-A5-CB-1 • Issued by Underwriters Laboratories Inc. • IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment • for measurement, control, and laboratory use, Part 1.
Be the first to review this product
Add your review: