ii900 Sonic Industrial Imager Pinpoints Leaks in Minutes
Description
According to the Compressed Air and Gas Institute (CAGI), the average compressed air system loses 30% of its air through leaks but locating those leaks has been a time-consuming and tedious process. The Fluke ii900 Sonic Industrial Imager enables maintenance teams to quickly and visually pinpoint the location of compressed air, gas, and vacuum system leaks even during peak production periods.
With minimal training, technicians can identify compressed air leaks considerably faster than using traditional diagnostic methods. Now checking for air leaks can be performed during the typical maintenance routine.
With an array of microphones combined with SoundSight technology, the handheld Fluke ii900 Sonic Industrial Imager filters out background noise so maintenance teams can accurately locate leaks in compressed air systems, even in the noisiest environments.
The 7-in. LCD touchscreen overlays a SoundMap on a visual image for quick leak location identification. The straightforward, intuitive interface allows technicians to isolate the sound frequency of the leak to filter out loud background noise. In a matter of hours, the team can inspect the entire plant. Images can be saved and exported for reporting purposes.
The Fluke ii900 was designed in partnership with Sorama, an Eindhoven-based company specializing in noise control and sound analysis solutions. The combination of Sorama’s long history and expertise in acoustic imaging and Fluke’s leadership in diagnostic industrial test and measurement equipment lead to the creation of a tool that has the durability and usability required for industrial maintenance applications.
Specs
- Do more with the same air compressors—delay the capital expense of purchasing an additional compressor
- Ensure proper air pressure to your pneumatic equipment
- Lower utility costs
- Reduce leak detection time
- Improve reliability in your production line
Sensors | |
---|---|
# of microphones | 64 digital MEMS microphones |
Frequency band | 2 to 52 kHz |
Sound pressure sensitivity | Detects a 0.005 CFM leak at 100PSI from up to 32.8 ft |
Operation distance range | 0.5 to > 70 m (1.6 to > 164 ft) |
Field of View | 63 ± 5° |
Minimum Frame Rate | 25 FPS |
Built-in digital camera (visible light) | |
Field of View | 63° ± 5° |
Focus | Fixed lens |
Zoom | 3 x Digital Zoom |
Display | 7-in. LCD with backlight, under-sunlight readable |
Resolution | 1280 x 800 |
Touchscreen | Capacitive |
Acoustic Image | Yes, SoundMap image |
Asset ID | QR code-based asset ID identification |
Photo notes | Up to 4 photos notes for reference |
Source | Show single or multiple sources |
Profile | Preset capture profiles |
Image Storage | |
Storage capacity | 20 GB |
Image format | Blended visual and SoundMap .JPG or .PNG |
Video format | Blended visual and SoundMap .MP4 |
Video length | 5 minutes max. |
Digital export | USB-C for data transfer |
Acoustic Measurements | |
Measurement range | 29.3 dB to 119.6 dB SPL (±2 dB) at 2 kHz 21.9 dB to 112.3 db SPL (±2 dB) at 19 kHz 36.6 db to 126.9 dB SPL (±2 dB) at 52 kHz |
Auto max/min dB gain | Auto or manual, user selectable |
Frequency band selection | User-selectable through user-made presets or manual entry |
Software | |
Ease of use | Intuitive user interface |
Trend graphs | Frequency and dB scale |
Spot markers | dB level reading at center point of image |
Battery | |
Batteries (field-replaceable, rechargeable) | Rechargeable Li-ion |
Battery life | 6 hours (product includes spare battery) |
Battery charging time | 3 hours |
Battery charging system | External charger |
General Specifications | |
---|---|
Standard palettes | 3: Grayscale, Ironbow, Blue-Red |
Operating Temperature | 0 to 40°C (32 to 104°F) |
Storage Temperature | -20 to 70°C (-4 to 158°F) Without batteries |
Relative humidity | 10% to 95% non-condensing |
Size (H x W x L) | 186 x 322 x 68 mm (7.3 x 12.7 x 2.7 in.) |
Weight (battery included) | 2.15 kg (4.74 lb.) |
Ingress Protection (IP) | IP40 protection |
Warranty | 2 year |
Self-diagnostic notification | Array-health test to identify when microphone array needs attention |
RoHS compliant | Yes |
Safety | |
---|---|
General Safety | IEC 61010-1 |
Electromagnetic Compatibility (EMC) International | IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1, Class A |
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication) |
USA (FCC) | 47 CFR 15 subpart B. |